[T2] Battery overflow on charge
Jim Denton 2thingswild at gmail.comThu Sep 4 23:56:28 MST 2014
- Previous message: [T2] Battery overflow on charge
- Next message: [T2] Battery overflow on charge
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ]
When charging a cold or fairly dead battery you want to get the electrode level above the plates but not up to the fill line. Once the battery is fully charged and hot from changing you can then fill it further if need be. On Fri, Sep 5, 2014 at 2:26 AM, John Kolak <jkolak at gmail.com> wrote: > I topped off a battery that had been sitting for a while to see if it > would hold a charge, filling to the bottom of the eye tubes as usual. > > But this time after charging overnight all of the cells overflowed > leaving a nice acid mess on the garage floor. Now all the cells are > only about half an inch below the top of the filler holes. > > Anyone have any idea why this happened? > > John > _______________________________________________ > type2 mailing list > type2 at type2.com > https://www.type2.com/lists/type2/listinfo >
- Previous message: [T2] Battery overflow on charge
- Next message: [T2] Battery overflow on charge
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ]
More information about the type2 mailing list