[T2] why won't it start
Jamie jrivers at globalserve.netMon Jun 8 14:48:33 MST 2015
- Previous message: [T2] why won't it start
- Next message: [T2] why won't it start
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ]
read this again... "Black wire on Neg is the double relay and white is the power from ignition that formerly went to fan" the NEG term on the coil should only have the trigger for the crane... and the trigger for the injectors, you can't feed the double relay from the NEG term on the coil.. and you can't put power from ignition that formerly went to fan to the NEG term.... I think you wrote this wrong... that white wire with the loom on it sure looks like the trigger to the injectors.. thru the ECU.... but if that white wire is power from ignition that formerly went to fan ,, then it goes on the POS + terminal.. the black wire that you say goes to the double relay.... IF it does go to term 86c on the double relay,, then it should be coming from the POS + term of the coil.. ----- Original Message ----- From: <accessys at smart.net> To: "Jamie" <jrivers at globalserve.net> Cc: <type2 at type2.com> Sent: Monday, June 08, 2015 12:23 PM Subject: Re: [T2] why won't it start > > near terminal is + far terminal is - > Black wire on Neg is the double relay and white is the power from ignition > that formerly went to fan. > > distributor has been set 90deg clockwise and still won,t start. in this > photo dist is set at 1TDC and crank, rotor, cap are all lined up.
- Previous message: [T2] why won't it start
- Next message: [T2] why won't it start
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ]