[T2] why it won't start
accessys at smart.net accessys at smart.netTue Jun 9 14:28:41 MST 2015
- Previous message: [T2] why it won't start
- Next message: [T2] why it won't start
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ]
I have owned this bus for over 20yrs and I don't thing I have ever been so frustrated. Bob On Tue, 9 Jun 2015, Pat Spragge/RFAN wrote: > Date: Tue, 9 Jun 2015 13:30:07 -0700 > From: Pat Spragge/RFAN <Pat.Spragge at rfan.com> > To: accessys at smart.net > Cc: Ken Madson <kenm at thebusco.com>, type2 at type2.com, > type2 <type2-bounces at type2.com> > Subject: Re: [T2] why it won't start > > adding this... > If it runs a sec or two on ether that would tend to indicate a fuel > problem. If you are using ether, I would disconnect the fuel > pump...relay/connection, etc....could be too much fuel getting in there > due to high fuel pressure. > Pat > > > > From: Pat Spragge/RFAN > To: accessys at smart.net, > Cc: Ken Madson <kenm at thebusco.com>, type2 at type2.com, "type2" > <type2-bounces at type2.com> > Date: 06/09/2015 01:25 PM > Subject: Re: [T2] why it won't start > > > with ether it sputters but still won't run. (but at least isn't > backfiring) > > Sputters? Does it sound like it is about to start or does it sound like > only a couple of cylinders are firing? When you checked spark, did you > check all 4 cylinders/plugs? If it runs a sec or two on ether that would > tend to indicate a fuel problem. Otherwise, spark/timing is suspect. > If fuel is the problem, would check pressure. If it doesn't sound like it > is almost running on ether, I would chase spark issues. > > There is something very basic that is being overlooked....gotta be fuel or > spark. > > Pat > > > > > From: accessys at smart.net > To: Ken Madson <kenm at thebusco.com>, > Cc: type2 at type2.com > Date: 06/09/2015 10:50 AM > Subject: Re: [T2] why it won't start > Sent by: "type2" <type2-bounces at type2.com> > > > > > went over everything with fine tooth comb. > > . compression 115-120 > . getting fuel injector firing > . moved wire on coil that was on wrong terminal (thanks Jamie) > . hot spark > . checked valve lash. (hydr) > . reset timing > > with ether it sputters but still won't run. (but at least isn't > backfiring) > am debating draining gas and putting in fresh.??? > > any other suggestions..??? > > thanks > Bob > (ps - 78 FI with auto tranny) > > > > On Mon, 8 Jun 2015, Ken Madson wrote: > >> Date: Mon, 8 Jun 2015 19:23:40 -0700 >> From: Ken Madson <kenm at thebusco.com> >> To: accessys at smart.net >> Subject: why it won't start >> >> Have you done a compression check? (I know it is a new motor, but . . .) >> >> >> >> I have had customers adjust hydraulic lifters in a turn or so and not > have >> any compression >> >> >> >> Regards, >> >> Ken Madson >> >> >> >> The Bus Company >> >> >> >> >> >> > > > _______________________________________________ > type2 mailing list > type2 at type2.com > https://www.type2.com/lists/type2/listinfo > >
- Previous message: [T2] why it won't start
- Next message: [T2] why it won't start
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ]
More information about the type2 mailing list